MSX Series Differential Pressure Transmitter

Series MSX Magnesense® Differential Pressure Transmitter
Monitors Differential Pressure, Air Velocity and Volumetric Flow
The Series MSX Magnesense® Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense® II transmitter for use in building control applications. The MSX simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges are available in Pa, mm w.c., and in w.c. All pressure ranges can be configured in unidirectional or bidirectional modes, providing a total of 32 ranges. The MSX transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification.

Date Sheet Available; MSX_2023

Product Applications
Filter monitoring in air handler units
Building pressure in pharmaceutical/semiconductor clean rooms
Duct static pressure in commercial buildings
Air velocity/flow in VAV systems

SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±1% FSO. Stability: ±1% FSO/year.
Temperature Limits: -4 to 158°F (-20 to 70°C).
Pressure Limits: Ranges 0 and 1: 3.6 psi max operation, 6 psi burst; Ranges 2, 3 and 4: 6 psi max operation, 6 psi burst.
Power Requirements: 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33VAC (3-wire).
Output Signals: 4-20 mA (2-wire); 0-10V or 0-5 V selectable (3-wire).
Response Time: Instantaneous (default) or 3 s (selectable).
Zero and Span Adjustments: Digital push-button.

This product is currently out of stock and unavailable.

SKU: MSX-W10-PA-2 Categories: , , Tags: ,

Series MSX Magnesense® Differential Pressure Transmitter
Monitors Differential Pressure, Air Velocity and Volumetric Flow

Please Note; MS2 is no longer available. However, MSX series is an alternative which has the selectable current or voltage output and a selectable range as well.

MSX-W10-PA DP Transmitter, Air MSX Wall, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output
MSX-W11-PA DP Transmitter, Air MSX Wall, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output
MSX-W12-PA DP Transmitter, Air MSX Wall, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output
MSX-W13-PA DP Transmitter, Air MSX Wall, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output

MSX-W10-PA-LCD DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output
MSX-W11-PA-LCD DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output
MSX-W12-PA-LCD DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output
MSX-W13-PA-LCD DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output

MSX-W10-PA-A481 DP Transmitter, Air MSX Wall, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output, Installer Kit
MSX-W11-PA-A481 DP Transmitter, Air MSX Wall, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output, Installer Kit
MSX-W12-PA-A481 DP Transmitter, Air MSX Wall, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output, Installer Kit
MSX-W13-PA-A481 DP Transmitter, Air MSX Wall, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output, Installer Kit

MSX-W10-PA-LCD-A481 DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output, Installer Kit
MSX-W11-PA-LCD-A481 DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output, Installer Kit
MSX-W12-PA-LCD-A481 DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output, Installer Kit
MSX-W13-PA-LCD-A481 DP Transmitter, Air MSX Wall, LCD, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output, Installer Kit

MSX-U10-PA DP Transmitter, Air MSX Duct or Wall, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output
MSX-U11-PA DP Transmitter, Air MSX Duct or Wall, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output
MSX-U12-PA DP Transmitter, Air MSX Duct or Wall, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output
MSX-U13-PA DP Transmitter, Air MSX Duct or Wall, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output

MSX-U10-PA-LCD DP Transmitter, Air MSX Duct, LCD, Uni or Bi, 25/30/40/50/60/75/100/125Pa, Universal Output
MSX-U11-PA-LCD DP Transmitter, Air MSX Duct, LCD, Uni or Bi, 25/40/50/60/100/150/160/250Pa, Universal Output
MSX-U12-PA-LCD DP Transmitter, Air MSX Duct, LCD, Uni or Bi, 250/300/400/500/600/750/1000/1250Pa, Universal Output
MSX-U13-PA-LCD DP Transmitter, Air MSX Duct, LCD, Uni or Bi, 1000/1500/2000/2500/3000/4000/5000/7000Pa, Universal Output

⚠WARNING: This product can expose you to chemicals including dichloromethane, which is known to the State of California to cause cancer, and bisphenol A (BPA) which is known to the to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Applications
Filter monitoring in air handler units
Building pressure in pharmaceutical/semiconductor clean rooms
Duct static pressure in commercial buildings
Air velocity/flow in VAV systems

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.